I am using S_AUJP V6 and have WB on Pin F14. Ground on Sensor Gnd, should it be on ECU Gnd? System is seeing WB but reading is not agreeing with gauge.
Have
WB OPT 1 (0x99A), b6 = AEM Linear AFR selected.
WB OPT 1 (0x99B), b7 - Sensor #1 PIN (0=F14; 1=A3) set at 0 for Pin F14
This is listed in Description of WB2 AFR-Sensor #1 of the ADX
L01C5 = WB AFR1
***VERY IMPORTANT***
YOU MUST ENTER THE CONVERSION EQUATION FOR THE WBo2 CONTROLLER BEING USED.
- If using an internally-supported controller,
the AFR Conversion Equation is: X / 10
- If using another controller, refer to
WBo2 Conversion Equations in the supplied
documentation.
***VERY IMPORTANT***
I have tried X/10 and the equation listed in the doc = (0.0464*X) + 7.3124
I have also tried the equation given by AEM (2.3750*X) + 7.3125
Readings still not agreeing.
Thanks
Chuck
Bookmarks