    Quote Originally Posted by lionelhutz View Post
    I love the 1 step at a time approach. No matter what system you're working with you've got to get it running before you can worry about doing anything more. It's the only way to learn and you're doing a good job on such an oddball system.
    Agreed. Getting it to run is a good plateau to rest on. Fuel pressure at 12-13 psi is good. I'd aim for as much common ground between the two systems as possible. Do you have the info to change the number of cylinders to three? I can dig that up...

  2. #2
    Super Moderator dave w's Avatar
    Join Date
    Feb 2011
    Posts
    6,345
    Quote Originally Posted by 1project2many View Post
    Agreed. Getting it to run is a good plateau to rest on. Fuel pressure at 12-13 psi is good. I'd aim for as much common ground between the two systems as possible. Do you have the info to change the number of cylinders to three? I can dig that up...
    When I change the cylinder select value, Hex address 0016 changes. I think changing the Hex value to 03 would be the correct value?

    See attached screen shot for an example of a 3 cylinder BPW (1.9 liters is half of a 3.8 liter V6 / figuring two 45 lb TBI injectors).

    dave w
    Attached Files Attached Files

  3. #3
    Administrator
    Join Date
    May 2011
    Location
    Lakes Region, NH
    Age
    54
    Posts
    3,868
    knumcyl is a divisor and lower number of cylinders results in a higher value. Three cylinder is 96d or 60h.

  4. #4
    Super Moderator dave w's Avatar
    Join Date
    Feb 2011
    Posts
    6,345
    Quote Originally Posted by 1project2many View Post
    knumcyl is a divisor and lower number of cylinders results in a higher value. Three cylinder is 96d or 60h.
    Interesting; see attached.

    dave w

  5. #5
    Fuel Injected! Willys43's Avatar
    Join Date
    Jan 2016
    Posts
    68
    Well gents I have never been able to stabilize the secondary computor. I finally abandoned the spark control and put an HEI dist with mechanically advanced spark. Starts and runs, first time every time.

  6. #6
    Super Moderator dave w's Avatar
    Join Date
    Feb 2011
    Posts
    6,345
    Thanks for the update.

    dave w

  7. #7
    Administrator
    Join Date
    May 2011
    Location
    Lakes Region, NH
    Age
    54
    Posts
    3,868
    Interesting to note. Are you talking about the AFR? Or the spark timing?

  8. #8
    Super Moderator Six_Shooter's Avatar
    Join Date
    Feb 2011
    Posts
    2,968
    Quote Originally Posted by Willys43 View Post
    Well gents I have never been able to stabilize the secondary computor. I finally abandoned the spark control and put an HEI dist with mechanically advanced spark. Starts and runs, first time every time.
    Have you tried swapping ECMs from "main" to "secondary" and visa-versa to see if it's an ECM issue?
    The man who says something is impossible, is usually interrupted by the man doing it.

Similar Threads

  1. Batch fire/Single Bank Fuel on 0411 possible
    By Fast355 in forum OBDII Tuning
    Replies: 4
    Last Post: 05-15-2015, 07:59 PM
  2. Batch fire sequence
    By myburb in forum GM EFI Systems
    Replies: 3
    Last Post: 03-14-2015, 07:05 PM
  3. UGH! need to squash SFI/batch fire argument
    By 34blazer in forum GM EFI Systems
    Replies: 22
    Last Post: 07-28-2013, 08:04 PM
  4. Need help tpi fire and stall confusion
    By Aholt91ss in forum GM EFI Systems
    Replies: 0
    Last Post: 06-29-2013, 11:16 PM
  5. Choosing injectors for batch fire MPI.
    By JeepsAndGuns in forum GM EFI Systems
    Replies: 24
    Last Post: 11-15-2011, 02:36 AM

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •