I looked, but not defined yet for MAF fails frequency. It should be easy fix. Any other stuff you may find useful that is missing.
I looked, but not defined yet for MAF fails frequency. It should be easy fix. Any other stuff you may find useful that is missing.
I don't know how hard it would be to create, but a speed density patch that could easily be removed would be helpful to lots of people I imagine.
I didn't notice anything else missing so far in MY poking around with it.
Takes a while to get used to looking at it when used to other platforms.
I can tell there has been a lot of work going in to this.
No need to re-invent the wheel. But we can make it better
Updated first post with latest tableseek file. It have some maf erro parameters defined.
A full ve patch have been on the to do list but still no free time to finish.
Some other cool features that are not widely known.
Search and compare a parameter accross multiple bin files.
Open tuner and goto Category view. Marked in red.
search_compare_1.jpg
Select a parameter and rigth click->search and compare->select bin files and wait a bit.
search_compare_2.jpg
I wonder if we could get the Admins of this fine site to make this thread a sticky?
No need to re-invent the wheel. But we can make it better
UPDATED first post with latest tableseek. Around 150+ more tables defined.
I will also point some of the less to guess features. It have been stated that universal patcher can open only single tables. Really annoying for looking at some of the transmission tables.
Actually universal patcher have built in a very advanced multitable view support, allowing to view all kind of table arrays 2d,3d,4d at once and on demand.
Here are some examples.
multitable_view.jpg
Mark multiple tables by holding ctrl+ mouseclick on table. All marked table will be displayed at once by the marking order.
Or to select more than one mark first, hold shift mark last.
HINT. looking trans shift table. rigth click on the tree explorer and select sort-> by address.
Sorting these by tablename is not recommended.
To benefit of the array, the naming must follow strict order, making use of . and []
Some example for setting an array can be seen at K_Dyna_Air_Coefficient[1].Predicted_1_Ahead_Correction_4 parameter, displaying all parameters from the array in a single table.
Other feature that is less known is the ability to compare different tables from the same bin. Both tables need to be of same format. For example high and low octane spark tables.
compare_different_tables.jpg
Question on Universal Patcher, I'm in the Tuner section and found a 'show histogram' tool, however when I try to use it for one of my csv data logs I get an error stating,
"Error, frmHistogram line 188: Object reference not set to an instance of an object."
Any ideas why that error is coming up? Not sure if I'm not understanding something fully when setting it up, or...
Thanks, this software is awesome!
EDIT: I also get an error stating the same but line 89.
Last edited by prider; 05-04-2022 at 11:56 AM.
That did it! If I'm remembering correctly I think I did have the bin loaded, but I definitely didn't have any of the tables open in the tuner section. Time to mess around with it!
This download doesn't seem to be working for me, what should I set the value for VTD_Configuration to? it's listed as unitless and has a current value of 1.
I also see VTD_Fail_Enabled_Bypass which has units of boolean and current value of 1
Background I have a 2006 6.0 and this is the stock computer, OS is 12587811
Get the latest tableseek file from here
http://www.gearhead-efi.com/Fuel-Inj...2&d=1651177148
Overwrite previous version in xml folder. Restart program.
Look at category DG_MAF
Not quiet sure what is in the zip folder, so just overwrite it. That is the latest published tableseek in the link.