Make sure your stoichiometric afr is set correctly for your fuel. Any change here will affect your ve tables. Your computer will calculate fueling using this value and your ve tables, then make adjustments using other tables such as Open Loop AFR vs Temperature vs Vacuum, PE AFR vs Temperature, etc. Everything working correctly depends on having your VE tables correct.