Quote Originally Posted by sturgillbd View Post
Attached is the edited bin file. My test bench isn't set up right now so I cant test the bin. Below are the calibration parameters.
Overheat temp for fan on 195
Fan on 185.5
Fan off 174.7
TPS for fan on 99.6
Minimum fan run time 30 sec
Fan doesnt come on with A/C - only coolant temp

Fan output is on pin E7. Remember this is a grounding output. It has to be used to control the negative side of a relay coil etc.
Copied file to my bin, not getting any response. Difference tool shows file highlighted as item not defined. ADX is different than mine, does that make a difference? My stuff is BHRJ5896 bin, Advanced $ODTP5v251 XFD, A217 $ODTP5v250 ADX. ADX for copied file is $8B-moded. I can get F-16 (I believe)canister purge to control a relay, but can only get 1 temperature on & off. E7 has no response except when you turn on the power. It grounds for a very short time and goes off.