  1. Replies
    7
    Views
    566

    Tks for update. I too have had cable issues, but...

    Tks for update. I too have had cable issues, but replaced with a new one and all OK. Failing cable worked for years and all of a sudden started providing random data. Really weird. Had one pin with...
  2. Replies
    36
    Views
    2,146

    Yes, but you need to make a log first, while...

    Yes, but you need to make a log first, while idling and running at various RPMs for a while, all in Closed Loop. Then post exported log .csv file and bin.
  3. Replies
    36
    Views
    2,146

    Just replace non-zero values with zeros and save...

    Just replace non-zero values with zeros and save it. However, might save-as so always have bin before and after changes. Applies to any changes you make. And keep written notes that accord with a bin...
  4. Replies
    7
    Views
    566

    One glitch is one too many. By any chance, are...

    One glitch is one too many. By any chance, are you using a ZIF socket in the ECM to connect the cable from the AutoProm? If so, Moates does not support that method of connection. It will work, but...
  5. Replies
    36
    Views
    2,146

    Yes, but apologies. What you are seeing in the...

    Yes, but apologies. What you are seeing in the pics is from the S_AUJP v7 XDF. Descriptions change among versions of XDF files. That's why the addresses of XDF items should be used and that's that I...
  6. Replies
    36
    Views
    2,146

    Difficult to read pics. I assume you want to zero...

    Difficult to read pics. I assume you want to zero the Low PW table. That would be the table in the left pic below.

    Voltage offsets (right pic) should not be zeroed. Rather, see the info below if...
  7. Replies
    36
    Views
    2,146

    Zero is correct for $8d representation of 8 cyls....

    Zero is correct for $8d representation of 8 cyls. Here's the text from the S_AUJP v7 XDF:

    VERY IMPORTANT: If changing this value from 8 cylinders (0), you must also change the entry at 0x293=ERROR...
  8. Replies
    36
    Views
    2,146

    Drew1992 -- Has this engine been running with...

    Drew1992 --

    Has this engine been running with an existing BIN or are you just beginning? If the latter, the BIN Dave provided is a good starting point. Spark may be a bit high for those heads and...
  9. Installing Bosch III Injectors Without Voltage Offsets

    Long post so please bear with me. Many replace GM factory Multec injectors, and others, with Bosch IIIs (B3)s of various flow rates and worry because they don’t have B3 Low Pulse Width (PW) and...
  10. Will need 2007 or higher.

    Will need 2007 or higher.
  11. Unfortunately this won't work Dave, but thanks...

    Unfortunately this won't work Dave, but thanks for the post. Macros are not supported in the Web Office version. Grrr.
  12. Thanks for the feedback. Yes, it will...

    Thanks for the feedback. Yes, it will unfortunately not run on any of the open source platforms (discontinued OpenOffice, LibreOffice, NeoOffice, ApacheOffice, etc.). This is because of differences...
  13. You can try it with OO, but it's not guaranteed...

    You can try it with OO, but it's not guaranteed to work because despite being an Excel clone, some operations have been reported as being different. But please try and report back. Also note that...
  14. Log Analyzer Quick Tuner -- Tuning Made Easy

    Attached is an updated Log Analyzer Quick Tuner program. Any .csv, .xls or .xlsx log file that contains BLM and INT with 128 as the base value is analyzed in just a few seconds, providing data to...
  15. Thread: File Upload

    by 84Elky
    Replies
    0
    Views
    1,251

    File Upload

    Hi Guys ---

    Unable to upload a zip file regardless of size. Tried several times with different size files. Rebooted and still no luck.

    Any ideas?

    Thanks.
  16. 1Proj -- Agreed. Thanks for your suggestions....

    1Proj --
    Agreed. Thanks for your suggestions. They along with others were considered during development, much like what was done in $12P with a staged shutdown if issues. But had to end somewhere to...
  17. Unlikely to add anything. Looked at what GM did...

    Unlikely to add anything. Looked at what GM did with the Buick GN turbo thinking using PWM for the solenoid would work by mirroring the CCP or EGR logic. But the GN is basically a somewhat dumb...
  18. S_AUJP Version 7 - Now Supports Turbo (August, 2021)

    Revision 2 November 22, 2021
    Provides:

    C4 Corvette CCM Commands.ADX


    For these cars, includes the CCM Commands that must be added to the S_AUJP ADX.


    Updated ADX files to allow cars with...
  19. Replies
    27
    Views
    8,384

    OK, here's a solution but it's not elegant. I...

    OK, here's a solution but it's not elegant. I have simulated it to ensure it works. But CAUTION:
    THIS SOLUTION ONLY APPLIES TO THE LATEST PRODUCTION RELEASE OF S_AUJP: S_AUJP v6-28.BIN...
  20. Replies
    27
    Views
    8,384

    If you are not proficient in assembly language...

    If you are not proficient in assembly language programming and don't have the ability to assemble the code into a bin file, ti is not possible. Perhaps if you explained exactly how it is working now...
  21. Replies
    6
    Views
    2,594

    Might try this. Works every time:...

    Might try this. Works every time: https://www.thirdgen.org/forums/diy-prom/761049-spark-advance-table-example.html#post6301288
  22. Replies
    1
    Views
    856

    Info as to engine, ECM, BIN mask, etc. would...

    Info as to engine, ECM, BIN mask, etc. would help. But in general, when a more radical cam is installed, vacuum at idle will be reduced which will require fueling changes at idle, and almost...
  23. Replies
    8
    Views
    2,083

    That's certainly close enough unless the heater...

    That's certainly close enough unless the heater is not working.
  24. Replies
    8
    Views
    2,083

    Tks for update. Unstable = perhaps not hot...

    Tks for update. Unstable = perhaps not hot enough? Will be interested to see if another ground helps. Some WBs require solid grounds apart from anything else. 14.1 does not mention grounds in their...
  25. Replies
    8
    Views
    2,083

    Yep, that's required. Glad it's now working....

    Yep, that's required. Glad it's now working. Would be interested in a follow-up post on how the NBo2 spartan2 simulation is working.